Overview, Cascadeable ez-screen – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 70

Advertising
background image

68

P/N 133487

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

68

P/N 140044 rev.

E

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP

Instruction Manual

Cascadeable EZ-SCREEN

To change (relocate) or clear (remove) previous fixed blanking, when:

Obstruction is relocated or cleared with EZ-SCREEN LP power OFF.

Clearing an Error Code 10 “Fixed Blanking Error” (begin at step #5, with the programming key switch in the Run position)

Clearing an Error Code 12 “Timeout Expired” (begin at step #6, with the programming key switch in the Program position)

Action

Indication

Comments

1

Remove power from EZ-SCREEN LP.

2

Locate or relocate the obstruction
(e.g., tooling, fixturing, etc.) in the
defined area and secure it, or if
clearing the fixed blanked area,
remove all obstructions.

3

Reapply power to the EZ-SCREEN
LP system.

EZA-RBK-1: rapid flashing
Receiver: Power-up Test Sequence.

All LEDs turn ON momentarily during
the Power-up Display Test Sequence.

4

An Error code 10 is generated when
one or more of the currently fixed
blanked beams become clear.

EZA-RBK-1: OFF
Receiver: display flashes “1”, “0”, status
LED flashes red.

5

Place the programming key switch
in the Program position (clockwise)
until step 8.

EZA-RBK-1: OFF
Receiver: display flashes “1”, “0”, status
LED flashes red.

6

Perform a valid reset (close the reset
switch for ¼ to 2 seconds, then open
it).

EZA-RBK-1: rapid flashing, then steady ON
Receiver: display sequences between “P”
“F” “A” and the number of blocked beams.

EZA-RBK-1 indicator flashes rapidly

to indicate the reset is in process.

• The timer resets to 10 minutes.
• Cascade systems: the first receiver

locks out in an Error Code 13.

7

If necessary, locate or relocate the
obstruction (e.g., tooling, fixturing,
etc.) in the defined area and secure.
If clearing the fixed blanked area,
remove all obstructions.

EZA-RBK-1: steady ON
Receiver: display sequences between “P”
“F” “A” and the number of blocked beams.

If an Error Code 12 occurs
(programming time out), repeat
step #6 above
(do not return the
programming key switch to the RUN
position).

8

Return the programming key
switch to the Run position (counter-
clockwise).

EZA-RBK-1: slowly flashes for
approximately 5 seconds
Receiver: display indicates “P” “F” “C”

This saves the new fixed blanking
configuration.

9A

Standalone (one sensor pair)
Trip Output:
the OSSDs turn ON.
Latch Output: After the EZA-RBK-1
indicator turns OFF, a valid reset
sequence is required.

EZA-RBK-1: OFF
Receiver: display indicates normal
operation.

9B

Cascade system (multiple
connected emitter-receiver pairs),

after the EZA-RBK-1 indicator turns
OFF:
Trip Output: Perform a single valid
reset, and the OSSDs will turn ON.
Latch Output: Two valid reset
sequences are required to turn ON
the OSSDs. Pause between the
reset actuations to allow the Error
code 13 to clear.

EZA-RBK-1: OFF
1st Receiver: Error Code 13.
Cascaded Receiver(s): display indicates
normal operation.

• A reset is required to clear the Error

Code 13 on the first receiver (i.e., the
receiver connected to the machine
control).

EZA-RBK-1 indicator ON when the

reset is actuated (closed) in normal
Run mode, flashes rapidly when
reset is in process.

Latch Output: the second reset is

required to clear the latch.

Advertising