Overview, Troubleshooting and maintenance, 1 troubleshooting lockout conditions – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 50: Warning

Advertising
background image

48

P/N 133487

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

Overview

48

P/N 140044 rev. E

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

EZ-SCREEN LP

Instruction Manual

Troubleshooting and Maintenance

5. Troubleshooting and Maintenance

5.1 Troubleshooting Lockout Conditions

Evaluate status indicators per Section 4.4. See Section 5.2 for

Test mode indication.
A Lockout condition causes all of the EZ-SCREEN LP’s OSSD

outputs to turn or remain OFF, sending a stop signal to the

guarded machine. Each sensor provides diagnostic error codes

to assist in the identification of the cause(s) of lockouts (see

Sections 5.1.1 and 5.1.2 or the Diagnostic Error Code label

supplied in the documentation pack). In addition, emitters in-

ternally monitor the infrared LEDs, and provide a health status

indication whenever one of these components has degraded.

The emitter will not lockout in this situation. Rather, the indi-

cation is intended to notify the user that the emitter should be

replaced soon.
The System provides easy methods for determining operating

problems. A Lockout condition is indicated by the following:
Emitter

Status indicator

Flashing Red

Diagnostic Display

Error code (flashing)

Receiver

Reset indicator

OFF

Status indicator

Flashing Red

Zone Indicators

OFF

Diagnostic Display

Error code (flashing)

Recovery Procedures

To recover from a Lockout condition, all errors must be corrected

and a single sensor reset sequence must be performed as

described below.

Emitter and Receiver Reset

Close the remote reset switch for 1/4 to 2 seconds and then

open the switch (per Section 4.3), or power the sensor down,

wait a second or two, then power it up.
NOTE:

If the receiver is set for latch output, a manual reset

using a remote switch, as described in Section 4.3, is

required to resume full operation.

WARNING . . .

Lockouts and Power

Failures

Power failures and Lockout conditions are indication of a problem

and must be investigated immediately by a Qualified Person.

Attempts to continue to operate machinery by bypassing the

EZ-SCREEN LP or other safeguards is dangerous and could

result in serious bodily injury or death.

WARNING . . .

Shut Down Machinery

Before Servicing

The machinery to which the EZ-SCREEN LP is connected

must not be operating at any time during major service or

maintenance. This may require lockout/tagout procedures (refer

to OSHA1910.147, ANSI Z244-1, or the appropriate standard for

controlling hazardous energy). Servicing the EZ-SCREEN LP

while the hazardous machinery is operational could result in

serious bodily injury or death.

Advertising