Overview, Cascadeable ez-screen, Warning – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 68: 10 remote fixed blanking, Programming key switch location, Ez-screen lp instruction manual, Use of reduced resolution and fixed blanking

Advertising
background image

66

P/N 133487

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

66

P/N 140044 rev.

E

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP

Instruction Manual

Cascadeable EZ-SCREEN

The Remote Fixed Blanking feature can be used on an

EZ-SCREEN LP cascade receiver as a stand-alone system

or as the end (slave) unit in a cascaded system. The remote

programming is only effective on that receiver. If fixed blanking

is required on other receivers in the cascade string, see Section

3.4.3 for DIP switch configuration information.

Programming Key Switch Location

The EZA-RBK-1 or an SPDT (Form C) switch is required to

perform the remote programming procedure, as shown in Figure

7-12. In addition, a normally open (N.O.) reset switch, such

as the EZA-RR-1, is generally recommended and is required

for systems configured for Latch output. A key-actuated switch

provides some supervisory control since the key can be removed

from the switch (see Section 3.1.3).
The Programming Key Switch must be:
• Located outside the guarded area,
• Located to allow the switch operator full unobstructed view of

the entire defined area, and

• Protected against unauthorized or inadvertent operation.

WARNING . . .

Use of Reduced Resolution

and Fixed Blanking

Use Reduced Resolution and Fixed Blanking only when
necessary.
Any holes created in the defined area either must be
completely filled by the blanked object or the safety (minimum)
distance must be increased to account for the larger resolution (see
Section 3.1.1).

DEE2R-8..D

DELPEF-8..D

(and in conjunction with

optional DEE2R-8..D)

RDLP-8..D

(or optional DELPE-8..D and QDE-8..D

combination – pin numbers shown)

CSB-M1281M1281

CSB-M1281M1281

BANNER EZ-SCREEN LP

with REMOTE FIXED BLANKING

CSB-M1281M1281

QDE-8..D

SLPCE..-....

SLPCR..-....

BANNER

EZA-RBK-1

REMOTE FIXED

BLANKING SWITCH

BANNER

EZA-RR-1

REMOTE RESET

SWITCH

(optional)

BANNER

EZ-LIGHT for

EZ-SCREEN

(optional)

OR

WHT #4

BRN #1

BLK #5

BLU #6

VL

T #8

RUN

PROGRAM

BANNER

T8LXXYP

EZ-LIGHT

BLU

WHT

SWAPABLE HOOKUP

to GUARDED MACHINE

7.10 Remote Fixed Blanking

As described in Sections 1.4.9 and 3.4.3, fixed blanking is

available to, in effect, “disable” beams that would otherwise be

continually blocked by a stationary object. One or multiple areas

within an EZ-SCREEN LP sensor pair may be “blanked out,”

with a minimum of one beam between two blanked areas. The

first sensing beam (synchronization beam) at the display end of

sensor must remain clear (can not be blanked); any other beam

may be blanked. All beams of a fixed blanked area must remain

blocked during operation in order for the OSSDs to remain ON.
On initial installations of cascadeable emitter/receiver pairs, when

they are used as a standalone system, the cascade configuration

procedure is not necessary.

Indicator Status

Programming Status

ON yellow

Programming in process

Flashing Yellow

Programming complete

OFF

Run mode

Figure 7-11. EZA-RBK-1 switch positions and

programming status indications

Figure 7-12. Connections for use of remote fixed blanking programming

NOTE: Cordsets and accessories listed here

are for example only.

Advertising