4.4 Status Indicators

A variety of status indicators are clearly visible on each emitter

and receiver face (see Figure 1-3 and Section 3.4.1, steps #3

and #4, and Section 7.7 for cascadeable models).
Emitter: A single bi-color Red/Green Status indicator shows

whether power is applied, and whether the emitter is in Run

mode, Test mode, or Lockout status. A 7-segment Diagnostic

Display indicates a specific error code when the emitter is in

Lockout; the display also momentarily indicates the scan code

setting at power-up or when changed.
Receiver: Bi-color Red/Green Zone indicators show whether a

section of the defined area is aligned and clear, or is blocked

and/or misaligned. A Yellow Reset indicator shows when the

System is in Run mode or is waiting for a reset. All models

have 8 Zone indicators, each of which indicates Blocked/Clear

conditions for approximately 1/8 of the total light screen.
A bi-color Red/Green Status indicator shows when the OSSD

outputs are ON (Green) or OFF (Red), or the System is in

Figure 4-4. Receiver status indicator operation (trip output configured)

Lockout status (flashing Red). A 7-segment Diagnostic Display

indicates the receiver’s trip (–) or latch (L) configuration setting

and displays a specific error code when the receiver is in

Lockout. The 7-segment display also momentarily indicates the

scan code setting at power-up or when changed.

Operating

Status

Status Indicator 7-Segment Diagnostic Display

Power-up

Red single-flash

Scan code flash 3x – sequentially

Run Mode

Green

Test Mode

Flashing Green

Flashing Red

Displays error code

(see Section 5.1)

or

Figure 4-3. Emitter status indicator operation

Operating

Mode

Reset

Indicator

Status Indicator

Zone

Indicators*

7-Segment Diagnostic Display

OSSD

Outputs

Power-up

OFF

Single-Flash Red

All Single-Flash Red

Scan code flash 3x – sequentially

OFF

Alignment Mode –

Beam 1 Blocked

OFF

Red

Zone 1 Red*

Others OFF

OFF

Alignment Mode –

Beam 1 Clear

OFF

Red

Red or Green

Total number of blocked beams

OFF

Run Mode –

Clear

ON

ON Green or

Flashing Green

All ON Green

ON

Run Mode –

Blocked

ON

Red

Red or Green*

Total number of blocked beams

OFF

Lockout

OFF

Flashing Red

All OFF

Displays error code (see Section 5.1)

OFF

* NOTE:

If beam 1 is blocked, Zone indicators 2-8 will be OFF, because beam 1 provides the synchronization signal for all the beams.

Flashing if Reduced Resolution is enabled.