Sdi-12 transparent mode – ADS Environmental Services Spider QR 775010 A0 User Manual

Page 113

Advertising
background image

ADS Environmental Services ADS Spider User Manual


Page 111

The minimum change for each input works in conjunction with the

Scan period

, which is common to all inputs and settable from this

page.

The same page also determines the logging of the 3 System
Monitors. These are 3 additional system inputs that monitor the
battery charger status, battery voltage, and system temperature.
System monitor logging is configured in a manner similar to that
described above.

You can exit at any time without making changes by clicking the

Cancel

link. Save the new values by clicking on the

Save

button.


NOTES:

1. You can mix Spider

s native inputs with the SDI-12 inputs as

required. To do that, simply select the required channel type
from the drop-down list in the

Type

column.

2. A channel reading of -99999 indicates that the Spider is not

able to communicate with the sensor. Check the SDI delay
(warm-up) time, verify the SDI address is set to 0, and check
all physical connections.

SDI-12 Transparent Mode

SDI-12 Transparent Mode is provided as an interactive tool for direct
communications with attached SDI-12 sensor(s). It allows users to
interrogate sensors, verify their operation, etc.

To enter the SDI-12 Transparent mode, access the

CHANGE

SETUP

page, as described in Setting up a Spider for the First Time

on page 32.

Click

SDI-12 Transparent Mode

. The following page will display:

Advertising