ADS Environmental Services Spider QR 775010 A0 User Manual

Page 70

Advertising
background image

ADS Environmental Services ADS Spider User Manual


Page 68

Command

Comment

Example

(x is 1

8)

yyyy PULSE
CNx

Pulse control x for 1 second
(x is 1

8) (PIN =yyyy)

1234 PULSE
CN4

GET REP

Request Daily Report
(available only if e-mail option
installed
)

GET REP


Web Access NOTE: Before access to the Spider is available over
the Web, a special text message must be sent to the Spider to wake
it up. Refer to Appendix D: Remote Access Configuration and Quick
Start Guide
on page 91 for further instructions and information.

After a Spider receives a text message command, it will interpret the
command and act on it. Invalid commands will be ignored. Valid
commands will be acknowledged with a return text message:

Location: OK Text Message command


Where,

Location

is the programmed Spider location

Text Message command

is the text message command


Therefore, once again using the programmed example, the
acknowledgement text message will be:

ADS DEMO STP: OK RST AL1


Control activation and deactivation commands may be protected with
a 4-digit PIN. If the PIN is set to

0000

, it is effectively disabled. Any

other 4-digit number will enable the PIN. You can change the PIN at
any time by accessing the Spider either remotely or locally with a
computer and entering the PIN, as described in Setting Location on
page 34.

NOTES:

1. Commands may be in lower case, upper case, or a

combination of both.