Auxiliary connectors – ADS Environmental Services Spider QR 775010 A0 User Manual

Page 30

Advertising
background image

ADS Environmental Services ADS Spider User Manual


Page 28

SENSOR RANGE

VALUE OF Rx

VALUE OF Ry

0

2.5V

None required

Leave out

0

5V

1 Kohm

¼

W metal film

1 Kohm

¼

W

metal film

0

10V

3.3 Kohm

¼

W metal

film

1 Kohm

¼

W

metal film


NOTE: You may be able to use the AUX 1 connector to supply the
power to the analog sensor. Please refer to Auxiliary Connectors on
page 28 for more information.

Intelligent Inputs (if installed)

SDI-12: Please refer to Appendix I: SDI-12 Operation on
page 108 for SDI-12 connection and operation details.

Auxiliary Connectors


SPIDER AUXILIARY CONNECTORS