Page 15

activated. When the trigger becomes active, the alarm is triggered
and the alarm sequence starts.
Alarms are completely independent from inputs. For example, an
input can trigger more than one alarm, each of which will send its own
special text message to its own special telephone numbers.

Text Messaging


If text messaging is enabled, a text message with the programmed
text will be sent to each telephone number, starting with the first. If
sending is successful, the unit will wait for 30 minutes (see following
note) for the user to acknowledge the alarm sequence.
Acknowledging the sequence stops the sending of text messages.

NOTE: The 30-minute waiting period referenced above for the unit
represents the default time period. The user can designate a period
anywhere between 0 and 60 minutes.

If sending is not successful (e.g., due to network congestion), the text
message will be sent to the same number after 1 minute. Up to three
attempts will be made to each number before proceeding to the next
number.

After the 3

rd

attempt to the 3

rd

number (if applicable), the unit will stop

sending text messages and wait indefinitely for the alarm to be reset.
This limits the number of text message transmissions per alarm to 9.

E-mailing (if e-mail option is installed)


If e-mail sending is enabled, an e-mail with the programmed text is
sent simultaneously to up to two addresses. If sending is successful,
no more e-mails are sent. If sending is not successful, up to 2 more
attempts are made at 3-minute intervals.