Spider power options, Always-on operation – ADS Environmental Services Spider QR 775010 A0 User Manual

Page 78

Advertising
background image

ADS Environmental Services ADS Spider User Manual


Page 76

Spider Power Options


The ADS Spider is designed specifically for low power, battery-
operated applications. The standard battery complemented with a
solar panel can provide sufficient power for many months of
unattended operation.

Two user-selectable options provide advanced power management
for special applications.









Always-on Operation


The ADS Spider is normally in the

sleep

state. This state is

indicated by a blank LCD display. The system automatically

wakes-

up

as required to scan analog inputs, log, receive & send text

messages and e-mails, etc. It remains

awake

for the shortest

possible time and then goes back to

sleep

.


The main advantage of the LP (Low Power) mode is greatly reduced
power consumption and increased battery life. The LP mode is the
default mode and recommended for most applications.

The disadvantages of the LP mode are the following:

1. Ethernet (Local Area Network- LAN) port is not available

during

sleep

.

2. Analog channels are not scanned during

sleep

.


It is possible to keep the system continuously

awake

by selecting

the

Always-on

power mode.

IMPORTANT NOTE:
Advanced power settings should only be changed by
experienced users. Selecting the

wrong

option can result in

an inability to remotely connect to a Spider, drastically reduced
battery life, or even complete battery failure.

Advertising