h2000 User Manual

114

HB-0845-06

CAL VAL 2

Setting

Function Text Shown

0 AFT

DPTH

1 FWD

DPTH

2 MID

DPTH

3 PORT

DEP

4 STBD

DEP

5 DEPTH

2

3.9 BATTERY

VOLTS

The h2000 monitors the yacht's battery supply and can be
shown on any display, giving a reading in volts. This is
calibrated by the manufacturer and should not require
adjustment except in exceptional circumstances or after a
system reset. If it is necessary to calibrate this function a
suitable voltmeter is required. The calibration value is found
in the menu under:

MOTOR

VOLTS, CALBRATE

CAL VAL1

Using the independent voltmeter, measure the battery
supply at terminals 18 (+) and 17 (-) at the Computer Unit
connection block.

Alter CAL VAL1 to match the value from the voltmeter.

3.10 SEA

TEMPERATURE

If a suitable temperature sensor is fitted, the h2000 will
monitor the current sea temperature.

The paddle-wheel has a sensor incorporated within it, in this
case no further action is required.

If the sensor is a totally independent fitting (B&G part no.
224-00-065) then it is necessary to change the sensor
selection value.

This value is found in:

Advertising