Linear functions will always be shown if selected by

CAL VAL 4 on linear 5. They will show no data if the
CAL VAL 1 is set to 1 or 2.

5.16.4 Expansion Processor Wiring

The Expansion Processor is connected to the system Fastnet
for power and data requirements.

TERMINAL FUNCTION

WIRE

COLOUR

1 Meter

5

SIN

Green

2 Meter

5

COS

Blue

3 Meter

6

SIN

Red

4 Meter

6

COS

Violet

5 Meter

7

SIN

Red

6 Meter

7

COS

Violet

7 Meter

8

SIN

Green

8 Meter

8

COS

Blue

9 Meter

Lighting

Yellow

10 Meter

Common

Orange

11 Meter

Ground

Black

12 N/C

13 N/C

14 Network

Data

-ve

Green

15 Network

Data

+ve

White

16 Network

Screen

Screen

17 Battery

Supply

Ground Black

18 Battery

Supply

12V

Red

19

Battery Volts Sense

Link to 18

20 N/C

21 Ground

Blue

22 Sensor

Supply

+6.5V

Red

23

Linear 5 Input

Green

24

Linear 6 Input

Green

25

Linear 7 Input

Green

26

Linear 8 Input

Green

27

Linear 9 Input

Green

28 N/C