B&G H2000 Pilot *DISCONTINUED* User Manual

Page 86

Advertising
background image

h2000 User Manual

86

HB-0845-06

3.

Press

Enter, the display shows the current Boat

Speed on the upper display with AUTO CAL
flashing below.

4.

Press

Enter, the display shows the current Boat

Speed with SINGLE flashing.

5. Press

Enter twice and display shows the default

setting for the actual calibration distance for each
run along the given course.

6. Press

Enter, the value for CAL DIST will flash.

The Scroll Up and Scroll Down Keys can now be
used to select the appropriate measured distance
(X). Press Enter to accept the new distance. The
system is now ready to start the first calibration
run.

7. Press Scroll Up and STRT RUN appears,

flashing.

8. When crossing the first transit mark of the run,

press Enter, the display now shows the current
Boat Speed with STOP RUN flashing.

9.

When crossing the transit mark at the end of the
run press Enter, the display shows the current
Boat Speed with END CAL flashing.

10. Press Scroll Down to select STRT RUN again

and repeat steps (8) and (9).

11. If only two runs are required, press Enter to end

calibration. The lower display will now show the
new calibration value which has automatically
been calculated by the Main Processor. This
should be recorded in the chart provided
(Appendix 1).

12. If a third run is required, press Scroll Down to

STRT RUN then repeat from step (8).

Advertising