Multiple linear sensor inputs installation sheet – B&G H2000 Pilot *DISCONTINUED* User Manual

Page 131

Advertising
background image

HB-0845-06

131

Green

(G)

Terminal

Function

Wire Colour

21

22

23

24

25

26

27

Sensor ground

Sensor Supply 6.5V DC

Air temp. input

Heel sensor input

Trim sensor input

Baro. sensor input

Lin. 4 sensor (spare)

Blue

(B)

Red

(R)

Green

38

41

Baro./Compass ground

Baro./Compass supply

Blue

Red

MULTIPLE LINEAR SENSOR INPUTS

INSTALLATION SHEET

41

38

27

26

25

24

23

22

21

20

Black

Orange

Violet

R

G

R

G

R

G

R

G

B

Bn

B

B

B

B

R

B

G

Blk

O

Y

V

B

R

B

R

R

B

B

Air Temp. Sensor

224-00-060

Linear 4

(spare)

SatNav output

Heel

Trim

Clinometers

690-00-004

Barometric Pressure Sensor

690-00-007

18 Way Junction box

386-00-023

7-core cable

20

SatNav ouput

Yellow (Y)

Cable

Use 7-core

from processor

to junction box

Sensors have

cable attached

(Blk)

(O)

(V)

MAIN PROCESSOR

TERMINALS

Notes
1. Inter-connect all sensor supply (Red wires) and sensor ground (blue wires) in the junction box. For
clarity, these connections have been omitted from this diagram.
2. Rotary Mast Sensor (RRF-ACP) connections: Red=21; Blue=22, Green=27

Advertising