Note

“Err” is displayed if the system encountered a problem

during the calibration run. For example, if the calibration
run distance was too short.

The log is now calibrated and the new calibration value is
stored permanently in the Main Processor memory.

3.2.6

Manual Calibration

The calibration values can be adjusted directly as follows:

1.

Select BOAT SPD in the upper display.

2. Press and hold the Scroll Down Key to select

CALIBRATE from the menu.

3. Press

Enter then press Scroll Down and the

display shows MANL CAL, which is the choice
that we require.

4. Press

Enter and the display shows SINGLE.

Notes

SINGLE is the choice required if a single paddle-wheel

or sonic speed is fitted.

If two paddle-wheels are fitted it is possible to access the

individual port and starboard calibration values: use the
Scroll Up or Scroll Down keys to select PORT CAL or
STBD CAL, as required. The Port and Starboard
calibration values refer to the sensor, i.e. port calibration
= port sensor (not “port tack”).

5. Press

Enter to reveal the current calibration value

in Hertz/knot.

6. To adjust the calibration value, press Enter and

the value flashes.

7. Use

Scroll Up or Scroll Down to change the

calibration value as required to the new
calibration value.