B&G H2000 Pilot *DISCONTINUED* User Manual

Page 43

Advertising
background image

HB-0845-06

43

The letters MS (Minutes/Seconds) and NM (Nautical Miles)
indicate that the function is running.

The letters RE denote RESET, where the function is zeroed
and waiting to be started.

The letters FR denote FROZEN, where the displayed value
is frozen, but the function is still counting in the
background.

2.6.1

Race Timer

1. With

TIMER MS shown on one half of the

display, press the Scroll key adjacent to the
opposite half of the display to display the
CONTROL menu. Press Enter to activate the
SET/START/STOP/SYNC loop function.

2. Scroll

to

SET and press Enter. The SET time

flashes. Using the UP/DOWN arrow keys, alter
the time (to a maximum of 120 minutes), press
Enter to confirm the time selected. This
automatically activates the START page.

3. When

START is selected, the current SET time is

transferred to the timer and it starts counting
down.

4. The other half of the display shows SYNC.

Pressing Enter will cause the timer value to be
reset to the nearest whole minute, pressing the
UP/DOWN scroll arrow continues the cycle.

5. When the timer reaches zero, the counter starts

counting upwards. Selecting START in this
condition resets the counter to the SET value and
starts counting down again.

When STOP is selected, the timer stops at whatever value is
currently displayed.

Advertising