5.14 Performance Processor NMEA Input and
Output Configuration

The Performance Processor has two NMEA inputs and two
NMEA outputs. However if the RS232 interface is required
then only one NMEA input and output can be used. The
inputs are optically isolated, as required by the standard, so
there is no direct electrical connection between the talker
device and the Hercules System. The input requirement is
half the minimum drive capacity of a standard NMEA
output.

The two outputs are identical and are capable of driving at
least two NMEA inputs each (four in total). If data is
available then NMEA information is output once a second.

5.14.1 Changing NMEA/RS232 Configuration

Changing the NMEA/RS232 configuration is carried out by
adjusting the calibration on Cross Track Error as follows:

1.

Select Cross Track Error on the display. If a page
has not already been set up to display cross track
error, then it can be found by cycling through the
options in the WAYPOINT Menu.

2. Using

the

Scroll Up and Scroll Down Keys scroll

to "CALBRATE" on the other half of the display.
Press Enter twice to show the current
configuration number (NMEA MDE).

3. Press

Enter, the configuration number flashes.

4. Use

the

Scroll Up and Scroll Down Keys to

change the number as follows:

Mode

Input 1

Output 1

Input 2

Output 2

0 183

183

RS232

RS232

1 183

183 - 183

4 -

183

183

183

The default setting is 0 for RS232 capability.