Table 6. RS232 Format

INPUT

OUTPUT

0

8 data bits (bit 7 ignored) no parity,
RTS handshake

7 data bits, even parity, CTS
Handshake

1

8 data bits (bit 7 ignored) no parity,
RTS handshake

7 data bits, odd parity, CTS
handshake

2

7 data bits, even parity RTS
handshake

7 data bits, even parity, CTS
handshake

3

7 data bits, odd parity RTS
handshake

7 data bits, odd parity, CTS
handshake

4

8 data bits (bit 7 ignored) no parity,
RTS handshake

7 data bits, even parity, no
handshake (CTS ignored)

5

8 data bits (bit 7 ignored) no parity,
RTS handshake

7 data bits, odd parity, no
handshake (CTS ignored)

6

7 data bits, even parity RTS
handshake

7 data bits, even parity, no
handshake (CTS ignored)

7

7 data bits, odd parity RTS
handshake

7 data bits, odd parity, no
handshake (CTS ignored)

5.15.3 Command Syntax

Commands are input as a string of ASCII characters starting
with a

#

character and a two-character command mnemonic

followed by data fields separated by commas. The command
is terminated and execution initiated by a carriage return
(CR).

A command line may not contain more than 88 characters
including the start

#

and the terminating carriage return

(CR). Data parameters may be omitted provided that if a
following parameter is needed the separating commas are
included.

For example:

####

IR,0,,NO DATA,(CR)