B&G H2000 Pilot *DISCONTINUED* User Manual

Page 40

Advertising
background image

h2000 User Manual

40

HB-0845-06

SECTOR ALARM - This is generated when the
heading leaves the safe sector as shown in Fig 2 -
Sector Alarm.

Example

-20° +20°

Heading

Safe Sector

Alarm Sector

Figure 2 - Sector Alarm

For example, when the SECTOR alarm is turned on, the
alarm reference heading is the current compass heading. If
the SECTOR alarm is set at 40 degrees, the sector value is
the compass heading +/- 20 degrees. It is therefore
important to switch the SECTOR alarm OFF before
carrying out a course alteration, switch the alarm ON again
when settled on the new course heading.

Any alarm can be switched ON and OFF individually, or all
alarms can be turned OFF collectively.

2.5.3

Set Lo Alarm - Depth

1.

Select DEPTH on the display.

2.

Press

Scroll Up or Scroll Down to scroll text

until ALARMS appears flashing.

3.

Press

Enter, text shows ALL OFF flashing.

Advertising