B&G H2000 Pilot *DISCONTINUED* User Manual

Page 115

Advertising
background image

HB-0845-06

115

TEMP

SEA TEMP, CALBRATE

CAL VAL1 (SENSORS)

The default selection value is 1, for the independent sensor
we need to change to 2.

3.10.1 Sea Temperature Offset Calibration

To calibrate SEA TEMP proceed as follows:

1.

Select SEA TEMP on upper half on FFD display

2. Press

Scroll Down until the lower text shows

CALBRATE flashing

3. Press

Enter, the lower text now shows CAL VAL

1 flashing

4. Press Scroll Down, the lower text now shows

CAL VAL 2 flashing

5. Press

Enter, the lower text now shows OFFSET

6. Press

Enter, the lower text now shows OFFSET

flashing and by use of Scroll Up/Down the
reference temperature may be entered.

7. Press

Enter, the offset value is accepted and the

upper display will show the adjusted measured
temperature.

This calibration can be carried out on either SEA TEMP ºC
or SEA TEMP ºF

The offset value is automatically converted so that both
degrees C and F are adjusted correctly.

3.11 TIMER

The Timer uses a stable quartz crystal to provide an accurate
time base when calibrated. The calibration is set when the
unit is manufactured and should not normally require further
adjustment. If adjustment is necessary the calibration can be
found as follows: