FGR2-PE Wirelss Data Transceiver

LUM0024AB Rev A

Page

Used To

RMS

Set FreeWave Redundant Master System units only. For details about
these settings, see the Redundant Master System User Manual Adden-
dum
.

Diagnostics

View the signal level, noise level, signal-to-noise delta, and receive rate for
each frequency available to the transceiver. For more information, see
"Viewing Transceiver Status and Statistics" on page 85.

Users

Setup logins for the transceiver. Up to nine custom users can be created
for each transceiver, with the admin user being the permanent tenth user.
For more information, see "Creating User Logins" on page 22.

Tools

Edit the site information and upgrade the transceiver’s Firmware. In a
MultiPoint Gateway, you can also enable the Global Change functionality.

The description and procedures in this manual are referenced as they appear in Tool Suite. If functionality is
available only through the configuration Web page, or is different than Tool Suite, the information is provided
as it displays in the Web pages, and indicates that you must use the Web page.

For more information about using Tool Suite, see the Tool Suite User Manual available on the User Manual
and System Tools
CD or by selecting File > Help in the Tool Suite software. For more information about the
configuration Web pages, see "Navigating the Web Pages" on page 19.

Reading Plus-Style Transceivers in Tool Suite

Prior to reading a transceiver's settings and programming a transceiver using Tool Suite, you need to know the
transceiver's IP address. For more information, see "Determining and Setting a Transceiver's IP Address" on
page 9.

In addition, the computer running Tool Suite must have an IP address within the same network. That is, the
first three octets of the IP address on the transceiver and the IP address on the computer running the Tool
Suite session must match. The last octet is unique. For information about changing a computer's IP address,
see "Changing the Computer IP Address in Windows" on page 121.

Note: For more information about using Tool Suite, see the Tool Suite User Manual

available on the User Manual and System Tools CD or by selecting File > Help
in the Tool Suite software.

1. Open Tool Suite and display the Configuration application.

2. Select or create an Ethernet network.

3. Enter the transceiver's IP address in the IP Address field in the upper left corner of the Plus

Configuration ribbon.

4. Click Read Radio in the Plus Configuration ribbon.

5. Tool Suite attempts to connect to the transceiver and display it in the Discovered Devices tree.

6. Select the transceiver in the Discovered Devices tree to display its current settings in the setup

tabs.