Programming point-to-multipoint extended call book – Baseline Systems FreeWave Ethernet Radio User Manual

Page 84

Advertising
background image

FGR2-PE Wirelss Data Transceiver

LUM0024AB Rev A

Number

(0)

884-1111

(1)

884-2222

(2)

000-0000

At times, you may want to force an Endpoint to go through a specific MultiPoint Repeater. In this scenario, the
Endpoint's Call Book should contain only the serial number for that Repeater as the entry on line 0.

Programming Point-to-MultiPoint Extended Call Book

In a MultiPoint network, an Endpoint can be programmed to roam between Gateways and Repeaters using the
MultiPoint Extended Call Book function. An Endpoint with its Call Book configured as below communicates
with any transceiver whose serial number appears in any of the three columns. Do the following to enable this
functionality:

1. Set the Network ID to 255.

2. In the Call Book, enter 999-9999 as the last entry in the first and second columns.

3. In the Call Book, set Entry to Call to All.

To set the call book in Tool Suite:

1. In the Tool Suite Configuration application, select the device to program and click the (2) Call

Book tab.

2. In the Number column in Row 0, enter the seven-digit serial number of the transceiver being

called.

3. In the Repeater 1 column, enter Repeater 1’s seven-digit number. If no Repeaters are being used,

leave the column empty.

4. In the Repeater 2 column, enter the second Repeater’s seven-digit number. If only one Repeater

is being used, leave the column empty.

5. If Repeaters are being used, select the appropriate Entry to Call option in the Master's Call Book.

To apply the changes, select either the Quick or All icon. Tool Suite applies the changes to the
transceiver.