Delta Alarm Enable

Web Parameter:

S-N Delta Enable check box in the SNMP Trap Limits section of the SNMP
page.

Network Type:

Both

Default Setting:

Disabled

Options:

Disabled, Enabled

Description:

Enables a trap for the calculated difference between the Signal Level and the
Noise Level of the transceiver. The trap condition is present based on the
settings in the Delta Alarm Below parameter.

Delta Alarm Below

Web Parameter:

S-N Delta Alarm Below in the SNMP Trap Limits section of the SNMP page.

Network Type:

Both

Default Setting:

30

Options:

Any whole number between 10 and 40 db in increments of 5.

Description:

If the Delta Alarm Enable option is set to Enabled, a trap condition occurs if
the calculated difference between the transceiver's Signal Level and Noise
Level goes below the value in this parameter.

Min Fault Time

Web Parameter:

Min fault Time (Seconds) in the SNMP Trap Configuration section of the
SNMP page.

Network Type:

Both

Default Setting:

300

Options:

30, 60, 90, 120, 150, 180, 210, 240, 270, and 300 seconds

Description:

The amount of time a trap condition must be continuously present before an
SNMP trap is sent to the Trap Manager(s).

Noise Alarm Above

Web Parameter:

Noise Alarm Above in the SNMP Trap Limits section of the SNMP page.

Network Type:

Both

Default Setting:

-100