Subnet mask, Syslog server 1, Syslog server 2 – Baseline Systems FreeWave Ethernet Radio User Manual

Page 50

Advertising
background image

FGR2-PE Wirelss Data Transceiver

LUM0024AB Rev A

Network Type:

Both

Default Setting:

Disabled

Options:

Disabled, Enabled

Description:

Enabling this parameter causes a Gateway to use the Spanning Tree Protocol
(IEEE 802.1D). This protocol eliminates the possibility of the transceivers
creating a network loop, which can cause network-wide problems.

Spanning Tree Protocol does use transceiver bandwidth, as any Spanning
Tree transceivers are constantly communicating their network “location.”
FreeWave recommends leaving Spanning Tree disabled, unless the Spanning
Tree Protocol is required in your application.

Subnet Mask

Web Parameter:

Subnet Mask in the LAN Network Interface Configuration section of the
IP Setup page.

Network Type:

Both

Default Setting:

255.255.255.0

Options:

Any valid net mask address in your network.

Description:

Used to route data in a sub-network. This parameter is typically set by a
network administrator.

Syslog Server 1

Web Parameter:

Syslog Server 1 in the Syslog Server section of the IP Setup page.

Network Type:

Both

Default Setting:

0.0.0.0

Options:

Any valid IP address.

Description:

The IP address of a system log server. If Push To Server is enabled, the
transceiver sends all log entries to the IP address entered in this parameter.

Syslog Server 2

Web Parameter:

Syslog Sever 2 in the Syslog section of the IP Setup page.

Network Type:

Both

Default Setting:

0.0.0.0

Options:

Any valid IP address.

Description:

The IP address of a second system log server. If system logging is enabled,
the transceiver sends all log entries to the IP address entered in this field. The
transceiver sends logs to both server entries, Syslog Server 1 and Syslog
Server 2
, concurrently. If a second server does not exist, enter 0.0.0.0.

34

Advertising