7

1.5.6

Preset Tare (Keyed Tare)

1. With the scale empty and display showing zero weight, press

.

2. Display will show (000000); the focused digit will flash.

3. To edit the value:

• Press or to select the digit.

• Press or to increment or decrement the value.

• Press

when the value is correct.

4. The display will change to the Net mode and the PT LED lights to show the preset tare was entered.

1.5.7

Display Tare

When a stored Tare value is displayed, the Gross and Net LEDs will be off and the

will be lit. To display a

stored tare:

1. Press .

2. Press

to

AUDIT.

3. Press

to

TARE

and press .

4. Press repeatedly to return to weighing mode.

If there is no tare in the system, the value displayed will be zero and the Gross and Net LED will be turned off.

See Section 9.12 for more information pertaining to the regulatory mode of operation.

1.5.8

Print Ticket

1. Press

to print either the Gross or Net format. When the accumulator is enabled and displayed, it is

used to print the accumulated value.

2. Wait for

LED to light.

3. Press

to send data to the serial port.

If

LED is not lit and the

PRINT

key is pressed, the print action will take place only if the scale comes out

of motion within 3 seconds. If the scale stays in motion for over 3 seconds, the PRINT key press is ignored.

1.5.9

Toggle Gross/Net Mode

1. Press

to switch the display mode between gross and net. If a tare value has been entered or

acquired, the net value is the gross weight minus the tare.

Gross mode —

Gross/Brutto

LED is lit.

Net mode —

Net

LED is lit.

1.5.10 View Audit Trail

See Section 3.2.

1. Press .

2. Press

to

AUDIT.

3. Press . The audit trail CALIB is displayed.

4. Press then or to CNT, TIME or DATE.

5. Press to view selected parameter.

6. Press twice to return to CALIB.

7. Press to the audit trail CONFIG and repeat steps 5 and 6 to view configuration number.

8. Press repeatedly to return to weighing mode.