6 normal mode commands, Normal mode commands – Rice Lake 480 Legend Series Digital Weight Indicator Installation Manual User Manual

Page 50

Advertising
background image

46

480 Operator’s Manual

6.1.6

Normal Mode Commands

The serial transmit weight data commands (see Table 6-12) transmit data to the selected port on demand. The SX
and EX commands are valid only in normal operating mode; all other commands are valid in either setup or normal
mode.

Command

Description

Values

GFMT

Gross demand print format
string

GROSS<G><NL2><TD><NL>

NFMT

Net demand print format string

GROSS<G><NL>TARE<SP><T><NL>NET<SP2><N>
<NL2><TD><NL>

ACCFMT

Accumulator demand print
format string

ACCUM <A><NL><DA> <TI><NL>

SPFMT

Setpoint print format

<SCV><SP><SPM><NL>

Table 6-11. PFORMT EDP Commands

Command

Description

Response Format

UID

View and set unit ID when in setup mode.
View only in normal mode.

nnnnnnn

DATESET

View and set date when in setup mode.
View only in normal mode.

MMDDYY, DDMMYY, YYMMDD, YYDDMM (enter using
DATEFMT specified)

TIMESET

View and set time when in setup mode.
View only in normal mode.

hhmm (enter using 24-hour format)

SX

Start streaming on Port 2.

The Trigger Mode of Port 2 must
be set to one of the four stream
modes for this command to
function.

OK or ??

EX

Stop streaming on Port 2

The Trigger Mode of Port 2 must
be set to one of the four stream
modes for this command to
function.

OK or ??

RS

Soft reboot

XA

Transmit accumulator value

nnnnnn UU
Where nnnnnn is the weight value, UU is the units.

XG

Transmit gross weight in displayed units

XN

Transmit net weight in displayed units

XT

Transmit tare weight in displayed units

XG2

Transmit gross weight in non-displayed units

XN2

Transmit net weight in non-displayed units

XT2

Transmit tare weight in non-displayed units

XE

Query system error conditions

nnnnn nnnnn
See Section 9.0 for detailed information about the XE
command response format.

Table 6-12. Normal Mode Commands