13 specifications – Rice Lake 480 Legend Series Digital Weight Indicator Installation Manual User Manual

Page 65

Advertising
background image

Appendix 61

9.13 Specifications

Model Numbers

United States

480-2A (AC) (NEMA 5-15)

International

Power – AC

Line Voltages

115 to 230 VAC

Frequency

50 or 60 Hz

Power Consumption

70 mA @ 115 VAC (8W)
35 mA @ 230 VAC (8W)

Fusing

2.5 A 5 x 20 mm fuse

Analog Specifications

Full Scale Input Signal Up to 35 mV
Excitation Voltage

5 ± 0.1VDC

Sense Amplifier

Differential amplifier with
4- and 6-wire sensing

Analog Signal

Input Range

Up to 7 mV/V

Analog Signal

Sensitivity

0.1

V/graduation minimum

0.5

V/grad recommended

Local Resistance

35-1140



Noise (ref to input)

0.5

V p-p

3

Internal Resolution

523,376 counts

Display Resolution

100,000 dd

Measurement Rate

37 measurements/sec

Input Sensitivity

38 nV per internal count

System Linearity

Within 0.01% of full scale

Zero Stability

13 nV/°C

4

Span Stability

13 ppm/°C

5

Calibration Method

Software, constants stored in
EEPROM

Common Mode

Voltage

AGND + 250mV V min

6

Excitation - 250 mV V max

Rejection

120 dB minimum @ 50 or 60 Hz

Normal Mode

Rejection

100 dB minimum @ 50 or 60 Hz

Input Overload

-0.3 V to Excitation +0.3 V

7

RFI Protection

Signal, excitation, and sense lines
protected by capacitor bypass and
ESD suppressors

Analog Output (Optional)

Type

Fully isolated, voltage or current
output,16-bit resolution.

Voltage output

0 –10 VDC

Voltage load resistance 1K

 minimum

Current output

0–20 mA or 4–20 mA

Current loop resistance 1200



maximum

Digital Specifications

Microprocessor

ARM Cortex M3 STM32F103ZET6

Digital Filters

Alphabeta and Averaging Motion Band
Update filters; software selectable

Digital I/O (Optional)

Type

Fully isolated

Digital Inputs

2 or 4 inputs, Opto isolated, 5 to 24
VDC input, active high

Digital Outputs

4 or 8 dry-contact relays
Up to 30VDC at 2A current

Serial Communications

Port 1

Full duplex RS-232

Port 2

Full duplex RS232, or output only
Active 20mA current loop.

Both Ports

1200 to 38400 bps; 7 or 8 data bits;
even, odd, or no parity; 1 or 2 stop
bits

Operator Interface

Display

6-digit LED display. 7-segment, 0.8 in
(20 mm) digits

LED annunciators

Gross, net, center of zero, standstill,
lb/primary units, kg/secondary units,
T, PT

Keypad

7-key flat membrane panel

Environmental

Operating Temperature –10 to +40°C (legal);

–10 to +50°C (industrial)

Storage Temperature

–25 to +70°C

Humidity

0–95% relative humidity

Enclosure

Enclosure Dimensions 9.5 in x 6 in x 2.75 in

24 cm x 15 cm x 7 cm

Weight

6 lb

Rating/Material

4X

Certifications and Approvals

NTEP
CoC Number

12-123

Accuracy Class

III/IIIL n

max

: 10 000

OIML

R76/2006-NL1-12.48

European Test Certificate

TC8322

European EC Type-Approval T5692

Accuracy Class

III n

max

: 10 000

Measurement Canada
Approval

AM-5892

Accuracy Class

III/IIIHD n

max

: 10 000

t

N

A

T

IO

NA

L CONFE

R

E

N

C

E

t

O
N

W

E

I G

H T

S A N D M

E

A

S

U

R

E

S

1

Calculated based on 350

x 10 load cells, 1x I/O card, 1x Analog card, 7 segment display.

2

The indicator was tested for EMC with a 380

 load cell; the maximal approved impedance is therefore 380 x 3 = 1140k

3

Measured during EMC tests per OIML R76-2006 (10v/m) without any digital filter in s/w; sampling rate was 4.7Hz.

4

Measured on an indicator with a simulator; the nominal zero stability of the ADC is 5 nV/°C.

5

Measured on an indicator with a simulator; the nominal span stability of the ADC is 1ppm/°C.

6

Based on the internal ADC specifications.

7

Based on the internal ADC specifications.

8

Based on the internal DAC specifications.