In table 6-9 – Rice Lake 480 Legend Series Digital Weight Indicator Installation Manual User Manual

Page 49

Advertising
background image

EDP Commands 45

Command

Description

Values

ALG.SOURCE

Analog output source

GROSS, NET

ALG.OFFSET

Zero offset

0%, 20%

ALG.ERRACT

Error action

FULLSC, HOLD, ZEROSC

ALG.MIN

Minimum value tracked

0999999

ALG.MAX

Maximum value tracked

0999999

ALG.MINNEG

Minimum negative

NO, YES

ALG.MAXNEG

Maximum negative

NO, YES

ALG.TWZERO

Zero calibration

065535

ALG.TWSPAN

Span calibration

065535

ALG.OUTPUT

Voltage or current output

CURRENT, VOLTAGE

Table 6-8. ALGOUT EDP Commands

Command

(n = setpoint number)

Description

Values

SP.ENABLE#n

Setpoint enable

OFF, ON

SP.KIND#n

Setpoint kind

GROSS, NET, -GROSS, -NET, OFF, DELAY

SP.VALUE#n

Setpoint value

number

SP.TRIP#n

Trip

Higher, Lower

SP.PREACT#n

Band value

number

SP.HYSTER#n

Hysteresis

number

SP.PUSHPR#n

Perform print when setpoint is satisfied

OFF, ON

SP.PUSHAC#n

Updates accumulator and performs a print
when setpoint is satisfied

OFF, ON

SP.PUSHTR#n

Perform Tare when setpoint is satisfied

OFF, ON

SP.DIGOUT#n

Digital outputs

NONE, 14

SP.BATSEQ#n

Batch type setpoint

OFF, ON

SP.BATCHG#n

Batching

OFF, AUTO, MANUAL

SP.WAITSS#n

Value must be stable

OFF, ON

Table 6-9. SETPNTS 1–8 EDP Commands

Command

(p = port number)

Description

Values

EDP.TRIGER#p

EDP port trigger

Port 1 – COMAND, DEMAND, PRN, NONE
Port 2 – NONE, PRN, STR-1, STR-2, STR-3, STR-4

EDP.BAUD#p

EDP port baud rate

1200, 2400, 4800, 9600, 19200, 38400

EDP.BITS#p

EDP port data bits/parity

8NONE, 7EVEN, 7ODD

EDP.SBITS#p

EDP port stop bits

1STOP, 2STOP

EDP.TERMIN#p

EDP port termination character

CR/LF, CR

EDP.EOLDLY#p

EDP port end-of-line delay

0255 (0.1-second intervals)

EDP.ECHO#p

EDP port echo

ON, OFF

EDP.PRNMSG#p

Enable print message when a
demand print is performed

OFF, ON

EDP.STRUR#p

Legal for Trade or industrial stream

STRLFT,STRIND

EDP.DEVMOD

Specifies the operating mode of
the indicator (see Section 9.4)

NONE, LOCAL, REMOTE

Table 6-10. SERIAL EDP Commands

Advertising