Appendix 53

Figure 9-3. STR-4: Cardinal Indicator Format

Figure 9-4. STR-2: Toledo Indicator Format

Demand Output Serial Data Format

The 480 uses a data string formatted in the print format parameters (depending on mode) for ticket printout. The
particular ticket format printed depends on the indicator configuration.

You can customize the ticket to work with a wide variety of printers, scoreboard displays, and other remote
equipment. See Section 7.0 for more information on custom print formats.

DEVMOD should be set to NONE to use demand output on port 2.
DEVMOD should be set to LOCAL to enable port 2 streaming.

Port 1 cannot be set to stream.

Carriage
Return

Polarity:
<+> for positive
"–" for negative

Six digits, right justified, floating decimal
(follows weight if not embeded),
leading zeroes are present.

g for Gross
n for Net

Hex value of <03>
is entered in string

lb = pound
kg = kilogram
g = gram
tn = ton (short)
t = ton (metric)
gr = grain
oz = ounce
<space> = none

Space
Character

<CR> <POL> <wwwwww> <S> <SP> <UNIT> <SP> <G/N> <SP> <SP> <ETX>

Space character

(2)

Space
Character

Status:
<space> = valid or invalid
m = motion
o = over/under range

<STX> <SWA> <SWB> <SWC> <wwwwww> <tttttt> <CR>

STX (02h)

Status Word A

<CR> entered at end
of string.

Status Word B

Status Word C

7

6

5

4

3

2

1

0

0

1

MUL1 MUL0

DP2

DP1

DP0

Parity

DP2 DP1 DP0 Fixed Zero/Dec. Pt. Location
0 0 0 x 100

(2 fixed zeroes)

0 0 1 x 10

(1 fixed zero)

0 1 0 x 1

(No decimal point)

0 1 1 x 0.1

(1 decimal place)

1 0 0 x 0.01

(2 decimal places)

1 0 1 x 0.001

(3 decimal places)

1 1 0 x 0.0001

(4 decimal places)

1 1 1 x 0.00001 (5 decimal places)

Disp. Div.
MUL1 MUL0 Multiplier
0 1 x 1
1 0 x 2
1 1 x 5

Even parity bit.
Requires EDP Port setup.

Status Word A:

7

6

5

4

3

2

1

0

0

1

Status Word C: ASCII 20h (space)

0

0

0

0

0

Even parity bit:
Requires EDP Port setup.

Parity

Status Word B:

7

6

5

4

3

2

1

0

0

1

0 = Gross Display Mode
1 = Net Display Mode

0 = Positive indicated weight value
1 = Negative indicated weight valu

e

0 = In range
1 = Out of range

0 = Stable
1 = Motion

0 = lb
1 = kg

Even parity bit:
Requires EDP Port
setup.

Parity

Six digits, right justified, dummy zeros, decimal
point with no leading zeroes except for immediately
preceding the decimal point. Leading zeroes
transmitted as spaces.

Tare Weight: Six digits, right justified, dummy zeros,
decimal point with no leading zeroes except for
immediately preceding the decimal point.
Leading zeroes transmitted as spaces.

Note