3 data formats, Table 9-3) – Rice Lake 480 Legend Series Digital Weight Indicator Installation Manual User Manual

Page 56

Advertising
background image

52

480 Installation Manual

Example:

If the annunciator status value returned on the ZZ command is 145, the gross, standstill, and lb

annunciators are lit. The number 145 represents the sum of the values for the standstill annunciator (128), gross
mode annunciator (16), and the lb/primary units annunciator (1).

9.3

Data Formats

Continuous Output Serial Data Format

When the TRIGER is set to DEMAND or PRN for port 1 or PRN for port 2, if continuous transmission is
configured for serial port 2 (port 2 TRIGER set to STR1, DEVMOD set to LOCAL), the 480 sends data using the
Consolidated Controls serial data format shown in Figure 9-1:

Figure 9-1. STR-1: Continuous Output Serial Data Format

Port 1 cannot be set to stream.

Data Formats Continued

Figure 9-2. STR-4:Weightronix Indicator Format

Decimal

Value

Annunciator

1

lb/primary units

2

kg/secondary units

4

Count

8

Tare entered

16

Gross

32

Net

64

Center of zero

128

Standstill

Table 9-3. Status Codes Returned on the ZZ Command

<STX> <POL> <wwwwwww> <UNIT> <G/N> <S> <TERM>

ASCII 02

decimal

Polarity:
<space> = Positive
<–> = Negative

Weight: 7 digits, right-justified, dummy
zeroes, decimal point with no leading
zeroes except for leading zero immediately
preceding the decimal point. Leading
zeroes transmitted as spaces.

L = pounds
K = kilograms
T = tons
G = grams
O = ounces

G = Gross

N = Net

Status:
<space> = valid
I = Invalid
M = Motion
O = Over/under range
Z = COZ

<CR> <LF>

or <CR>

Note

Space

Polarity:
<+> for positive
"–" for negative

Six digits, right justified, floating decimal,
leading zeros are present

g for Gross
n for Net

<CR><LF>
or
<CR>

lb = pound
kg = kilogram
g = gram
tn = ton (short)
t = ton (metric)
gr = grain
oz = ounce
<space> = none

Space

<SP> <G/N> <POL> <wwwwww> <SP> <UNIT> <TERM>