TABLE 9-10. EXPLORER INTERFACE COMMAND LIST (continued)

Command
Characters

1)

Function

PSN

Print Serial Number.

PV

Print base software version, terminal software version and LFT ON (if LFT is set ON).

x#

Set Counting APW (x) in grams. (must have APW stored)

P#

Print Counting application APW.

x%

Set Percent application reference weight (x) in grams. (must have reference weight stored)

P%

Print Percent application reference weight.

xAW

Set Dynamic Weigh Level to x. (x = 1 - 99 seconds)

xAW

Set Dynamic Weigh Mode. x = A (Automatic), S (Semi-Automatic), M (Manual)

PAW

Print Dynamic Weigh Level.

BAW

Start Dynamic Weigh cycle. (Manual Mode)

CW

Clear locked weight (weight < threshold) in Dynamic Weigh (same as button “Reset”) & Display
Hold (same as button “End Peak Hold”).

xCO

Set Checkweighing Over Limit in grams x.

xCU

Set Checkweighing Under Limit in grams x.

PCO

Print Checkweighing Over Limit.

PCU

Print Checkweighing Under Limit.

xCM

Set Checkweigh mode (1=over/under, 2=target/% tolerance, 3=Target/weight tolerance

xCT%

Set Checkweighing target in grams x for percent tolerance mode.

PCT%

Print Checkweighing Target for percent tolerance mode.

xCTW

Set Checkweighing target in grams x for weight tolerance mode.

PCTW

Print Checkweighing Target for weight tolerance mode.

xC%

Set Checkweighing % tolerance x. Attention: when x is a positive value, it is used to set the
+tolerance value; vice versa.

PC%

Print Checkweighing % tolerance.

xCW

Set Checkweighing weight tolerance x. Attention: when x is a positive value, it is used to set
the +tolerance value; vice versa.

PCW

Print Checkweighing weight tolerance.

xDH

Set Display Hold mode (Peak Hold). x = A (Automatic), S (Semi-Automatic), M (Manual)

xD

Set 1 second print delay (set x = 0 for OFF, or x = 1 for ON).

xFL

Set filter level to x (1 = low, 2 = med, 3 = high).

xAL

Set Auto-zero to x (x = 1 for 0d, x = 2 for 0.5d, x = 3 for 1d, x = 4 for 3d).

Esc R

Resets all Balance menus to factory defaults. Attention: The binary code of this commands is
“1B 20 52 0D 0A” or “1B 52 0D 0A”.

PID

Print current user Name.

xID

Program user Name. Attention: only allowed numeric input.

xTL

Set Totalize Mode. x = A (Automatic), M (Manual).

PTIME

Print current time.

PDATE

Print current date.

xTIME

Set Time, x format: hh:mm:ss.

xDATE

Set Date, x format: mm/dd/yyyy.

CA

Continuous weight, same as CP.

SA

Stable load, same as SLP.

xA

Interval Print x = interval in sec (1-3600) 0 = off, same as xP.

0A

Set AutoPrint off, same as 0P.

SC

Begin Span Cal, same as C.

xAM

Set Animal Mode to Auto, Semi-Auto, Manual. Same as xAW(A/S/M)

?

Prints current mode, same as PM.

xS

0 = print unstable data, same as IP; 1 = print stable only

1)

, same as SP.

xRL

0 = disable response; 1 = enable response. This command only controls the “OK!” response.