Rice Lake MSI4300 PortaWeigh Plus Crane Scale 7 Key User Manual

Page 15

Advertising
background image

Page 14

MSI-4300 Porta-Weigh Plus/7 Key

User Guide

M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

the previous settled reading has been replaced. The last settled reading
is what will be used for totalizing when the scale returns to zero. The
user must take caution that when removing the load the scale does not
go out of Motion or a possibly erroneous reading could occur. The last
settled weight is actually added to the total when the scale returns to
less than 1% of full scale. The Total LED will flash for a steady 4
seconds indicating the weight has been totaled and the total value will
be shown briefly.

Note: MSI can modify or supply the Porta-Weigh Plus with a “maxi-
mum settled weight mode” AutoTotal. Contact factory for details.

Action:

AUTO

Push TOTAL.

1)

The message "TOTAL ON" appears briefly, then "AUTO

"

annunciator.

2)

Pick up the weight to be totalized. The LED will flash three
or more times when the weight is settled.

3)

Set down the weight. The screen displays the new total and
will indicate “x TOTAL ” where x is the number of totaled
weighments up to 9999.

The total key is used as a Total Enable, Total Off, toggle key
which is indicated briefly on the message display (i.e.
“TOTAL ON” or “TOTAL OFF”. Auto Totalizing will only
occur in the TOTAL ON mode.

The Auto Total On mode is indicated by an “AUTO

annuciator on the LCD .

Advertising