Tare memory – Rice Lake MSI4300 PortaWeigh Plus Crane Scale 7 Key User Manual

Page 27

Advertising
background image

Page 26

MSI-4300 Porta-Weigh Plus/7 Key

User Guide

M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

TARE MEMORY

Function:

Allows storing and recalling a numeric or Semi-Auto Tare
value. Up to 10 digital or Semi-Auto Tare values can be
entered including the standard Tare available directly on the
keyboard.

The following functions are available: Apply a previously
stored tare, store the current weight in Tare Memory (Semi-
Auto Tare), enter a weight manually and store it in Tare
Memory (Keyboard Tare), modify a previously stored Auto
or Keyboard Tare.

Rules for Use:

1)

The input value must be greater than zero and at least 1
display increment.

2)

When storing an Auto Tare, the motion annunciator must be
off. The manual keyboard total function is independent of
motion and can be applied at any time.

3)

Will not work in the Peak Gross or Peak Net modes.

4)

Values can only be entered or applied when gross weight is
the current weighing mode. However, the values associated
with each Tare memory can be reviewed.

Action:
Selection is made of 1 of 10 Tare Memory values. The selection is
then Set or Entered into to store or modify. An empty Tare Memory is
designated by a zero and can not be used until a positive value is
stored.

To apply a stored tare value:

1)

Push SHIFT TARE MEMORY.
The liquid crystal display provides the value and number of
the Tare memory. The numeric digits display the value stored

Advertising