Auto off – Rice Lake MSI4300 PortaWeigh Plus Crane Scale 7 Key User Manual

Page 20

Advertising
background image

MSI-4300 Porta-Weigh Plus/7 Key

User Guide Page 19

M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

The actual FS range of the scale is dictated by the units in which it
was calibrated in. For example, a 10,000 X 2 lb scale has a maximum
overload of 10,400 lbs. If the units were changed to kgs by the setup
menu, the range before overload would be 4717 kg (10,400 x .4536).
The resolution will round out to 1 kg in this example. (Not available in
some legal-for-trade systems).

To change Unit settings:

1)

Push SHIFT SETUP (Unless you are already in the Setup
menu).

2)

Push SELECT until the message display reads "UNITS".

3)

Push ENTER. You are now in the Units menu.

4)

Push SELECT until the desired units are displayed, then
press ENTER .

5)

Now you are back in the Setup menu. Push CLEAR to return
to normal operation or push SELECT to scroll to a different
setup operation.

AUTO OFF

The AUTO OFF feature when enabled prolongs the battery life of the
scale by turning the power off after 1 hour of non use. Any time a key
is depressed (any key), or the detected weight is in motion, the 1 hour
limit is reset. Therefore the scale will stay on indefinitely if the weight
is changing or any key is pressed at least once an hour. This feature
defaults to the enabled mode when initially calibrated. When disabled
the scale will stay on, only the power key will turn it off.

To change the Auto Off mode:

1)

Push SHIFT SETUP (Unless you are already in the Setup
menu).

2)

Push SELECT until the message display reads "AUTO-
OFF".

3)

Push ENTER. You are now in the Auto-Off menu.

4)

Push SELECT to toggle between "ENABLED" and "DIS-
ABLED". When the desired mode is displayed, push EN-
TER.

5)

Now you are back in the Setup menu. Push CLEAR to return
to normal operation or push SELECT to scroll to a different

Advertising