MSI-4300 Porta-Weigh Plus/7 Key

User Guide

M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

the form of “TARE x” (where x = the tare memory number
from 1 to 9 or is left blank for the base tare memory). Use the
SELECT key to scroll to the Tare memory number that you
wish to store the value in. (Infrared remote users can key in
the Tare Memory number directly).

2)

Push ENTER. This enables the "AUTO x" store function.

3)

Push SELECT. This enables the manual keyboard tare value
entry. The message display reads "INPUT Tx". The far left
digit on the numeric display will flash. If a value was
previously stored the value flashing will be the last entered
Tare. This allows easy modification. All digits must be
entered, therefore small tare values must be preceded by
leading zeros.

Note: With Remote Control option, the Tare value can be
entered directly from the numeric keypad. Skip to step 6.

4)

Use the SELECT key to change the flashing digit. When the
desired digit is displayed, push ENTER.

5)

Repeat step 4 for the remaining digits.

6)

When the last digit is entered the ENTER key is pushed again
to return to the Tare Memory menu, or the CLEAR key can
be used to delete the entire value and start over.

7)

At this point the TARE key can be pushed to immediately
apply the new tare or the SELECT key can be used to select
another Tare Memory for entry or modification.

To manually enter a stored tare value (keyboard tare):

1)

Push SHIFT TARE MEMORY.
The liquid crystal display provides the value and number of
the Tare memory. The numeric digits display the value stored
and the message display indicates the tare memory number in
the form of “TARE x” (where x = the tare memory number
from 1 to 9 or is left blank for the base tare memory). Use the
SELECT key to scroll to the Tare memory number that you
wish to store the value in. (Infrared remote users can key in
the Tare Memory number directly).

2)

Push ENTER. This enables the "AUTO x" store function.

3)

Push SELECT. This enables the manual keyboard tare value
entry. The message display reads "INPUT Tx". The far left
digit on the numeric display will flash. If a value was
previously stored the value flashing will be the last entered
Tare. This allows easy modification. All digits must be
entered, therefore small tare values must be preceded by