Lo setpt (setpoint), Set point entry, Hi setpt (setpoint) – Rice Lake MSI4300 PortaWeigh Plus Crane Scale 7 Key User Manual

Page 23: S e t point entry

Advertising
background image

Page 22

MSI-4300 Porta-Weigh Plus/7 Key

User Guide

M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

HI SETPT (SETPOINT)

When the weight exceeds the set value the Porta-Weigh Plus can
respond in a variety of ways. The normal response of the HI SETPT is
to turn on an open Drain MOSFET which can be used to drive relays,
lights, sirens, etc. (Contact the factory or your distributor for more
details). Other HI SETPT responses possible are to blank the display
or flash the reading on and off.

LO SETPT (SETPOINT)

When the weight falls below the set value, the Porta-Weigh Plus can
respond in a variety of ways. The normal response of the LO SETPT
is to turn on an open Drain MOSFET which can be used to drive
relays, lights, sirens, etc. (Contact the factory or your distributor for
more details). Other LO SETPT responses possible are to blank the
display or flash the reading on and off. The Lo Set Point can be
configured by customer order to become a second “greater than” a
value response. This is typically used in overload warning systems
and is standard in audible alarm option equipped units.

S E T

POINT ENTRY

A Set point is entered by the following procedure:

1)

Press SHIFT ZERO to get into the Setup Menu.

2)

From the Setup function, push the SELECT key until the
message reads “HI SETPT” (or “LO SETPT”)

2)

Push ENTER. This accepts that the HI SETPT can be
entered.

3)

The message display reads “HI VALUE”. Push ENTER.

4)

The most significant digit flashes. Display reads “INPUT
WT”. Push the SELECT key until the first digit of the desired
weight value is displayed. Push ENTER. (The "CLEAR" key
can be used to change an entry if needed)
Note: To enter, for example, 100kgs on a 10,000 kg scale, the
first two digits should be entered as zeros (00100).

5)

The next most significant digit flashes. Use the SELECT key
and the ENTER key to finish out the value entry.
Note: With the IR Remote the value can be directly entered)

6)

After the entire Hi Set Point is entered the display will step to
“MODE”. Push ENTER. The first selection is “DISABLED”.
This mode allows the user to program a set point without the

INDIVIDUAL DIGIT FLASHES EVERY

TIME SELECT KEY IS PUSHED.

Advertising