To disable a set point – Rice Lake MSI4300 PortaWeigh Plus Crane Scale 7 Key User Manual

Page 25

Advertising
background image

Page 24

MSI-4300 Porta-Weigh Plus/7 Key

User Guide

M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

menu and back to standard scale operation. Use the same
procedure for a Low Set Point.

TO DISABLE A SET POINT

It is often useful to be able to set up a Set Point ahead of time and
disable it for testing purposes.

1)

From the Setup function, push the SELECT key until the
message reads “HI SETPT” (or “LO SETPT”).

2)

Push ENTER. This accepts that the HI SETPT is to be
modified.

3)

Push SELECT until the “MODE” message appears. Push
ENTER.

4)

Push the SELECT key until the message “DISABLE”
appears. Push ENTER. This disables the Set Point and
returns you to the Set Point Menu.

5)

Push CLEAR two more times to get out of the SetPoint and
Setup menus, or using the SELECT key, scroll to the next
desired operation. To re-enable the Set Point, follow steps 1-
3 above. On step 4 select the “GROSS” mode or the

Advertising