M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

use provided by 8 alkaline ‘D’ cells. Maximum battery life is
reduced by use of the backlighting; full time low light
operation will provide up to 400 hours of operation. A typical
operating cycle of 8 hours daylight use and 2 hours night use
will provide 10 months of operation on a single battery.
The Porta-Weigh Plus will automatically power down when
not in use (this feature can be disabled). And a low battery
indication appears when approximately 10% of battery life
remains.

Easy to maintain: Full digital calibration assures reliable,
repeatable measurements.

Selectable for lbs, kg, tons, and metric tons unless prohibited
by regulations.

Automatic or manual weight totalization for loading opera-
tions.

Complete marine sealing ensures reliable operations under
harsh weather conditions.

Anti-EMI shielding standard. Low emissions and susceptibil-
ity.

Easily customized for special applications.

Up to 10 recallable Tare memories stored manually or
automatically.

Peak Hold mode for stress analysis.

2 set points can be set for any in-range weight for operator
alerts or process control. External setpoint outputs available.
(Contact factory for information).

Silicon elastomeric rubber switches, which are more rugged
than mechanical switches, provide 10 million operations.
They can withstand excessive impact without affecting
operation. Rubber membrane provides watertight seal.
Additional poly shield on underlay provides second layer of
integrity and prevents humidity contamination.

INFRARED REMOTE CONTROL FEATURES

The infrared remote control option allows all features of the scale to
be operated at distances up to 10 meters from the scale. This rugged
option is shock proof and waterproof. In addition to remote operation
of all the standard modes of the scale the following features are added:

9 ID codes. This feature provides the user with the ability to
store up to 9 separate totalizations. Keeping track of indi-
vidual loads is simpler than ever. Each of the 9 totalizations
can go up to 999999 counts.

Numeric entry of tare values and set points.