Rules for Auto Total:
1)
The scale cannot be in motion. An auto total acceptable
reading is indicated by three or more short flashes of the
Total LED.
2)
Weight readings must be greater than 2% of FS or “Min e”
(whichever is greater) relative to Net Zero or Gross Zero.
3)
Each reading added to total must be preceded by a return to
zero (Net or Gross)
±
1% of FS. Totalization of the last settled
weight is indicated by a 4 second flash of the Total LED.
VIEW
∑
(TOTAL)
Function:
Displays the current Total value and allows the total to be cleared.
Action:
To display the current Total Value:
Press VIEW
∑
.
The message display will read “TOTAL” and the total value is
displayed on the numeric digits. The Total Value will stay displayed
until VIEW
∑
is pushed again. The number of totalized weighments is
displayed on the far left of the message display.
To clear a stored Total Value:
While in the “VIEW
∑
” mode, press VIEW
∑
, SHIFT & CLEAR .
The total reading and the number of weighments counter will revert to
zero.