Filter, Units – Rice Lake MSI4300 PortaWeigh Plus Crane Scale 7 Key User Manual

Page 19

Advertising
background image

Page 18

MSI-4300 Porta-Weigh Plus/7 Key

User Guide

M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

FILTER

Use the LOW setting for most scale applications. It settles fastest and
is intended for general use. Use the MEDIUM setting when the scale
is being used under conditions that cause light to medium swinging.
Use the HIGH setting when there is a lot of scale motion. There is a
time penalty when using the HIGH setting. The user should wait at
least 5-15 seconds to ensure that the final reading has settled (motion
indicator off). (Not available in some legal-for-trade systems)

To change the filter settings:

1)

Push SHIFT SETUP (Unless you are already in the Setup
menu).

2)

The message should read "FILTER". If it does not, push
SELECT until it does.

3)

Push ENTER. You are now in the Filter menu.

4)

Push SELECT to change from LOW, MEDIUM or HIGH
settings. When the desired filter setting is displayed on the
message display, push ENTER.

5)

Now you are back in the Setup menu. Push CLEAR to return
to normal operation or push SELECT to scroll to a different
setup operation.

UNITS

Units can be changed by scrolling through the choices with the
SELECT key and pushing ENTER when the desired unit is displayed.