SPECIFICATIONS

Accuracy

±

0.1% of applied load for all capacities 100,000 lbs (50,000 kg)

and below

±

1.0% > 100,000 lbs (50,000 kg)

Maximum Resolution

12,500 displayed counts
50,000 to 80,000 counts internal

Standard Industrial Resolution

5000 displayed counts

Display

6 digit 1.6"/40 mm high numeric liquid crystal (weight display)
8 digit 0.8"/20 mm high alphanumeric liquid crystal display
(message / units display)
Annunciators for measurement modes
Sunlight visible light emitting diode indicator for Totalization
Photocell activated electroluminescent backlighting

Filtering:

Low, Medium, High (switch selectable)

Power:

8 standard D Cells

Operating Time:

2000 hours typical with occasional use of the LCD backlight. 400
hours with continuous use of backlight.

Temperature Range

-20

°

C to +60

°

C Operating (-4

°

F to 140

°

F)

-40

°

C to +80

°

C Storage (-40

°

F to 176

°

F)

Enclosure

NEMA IV, Alodined cast aluminum

Safe Overload

200% of rated capacity

Ultimate Overload

500% of rated capacity except 70,000 and 100,000 lb models,
450% of rated capacity

Hook

Crosby-Laughlin S-1 Timken Bearing swivel hook or equivalent

Top Eye Nut

500 through 30,000 pound capacity, Crosby-Laughlin or equiva-
lent

Top Shackle

50/70/100,000 pound capacity, Crosby-Laughlin or equivalent