9 battery pack, 1 battery life, 2 battery use guidelines – Rice Lake MSI-4260 Port-A-Weigh User Manual

Page 14: Battery life, Battery use guidelines

Advertising
background image

10 MSI-4260 Port-A-Weigh Operator’s Manual

1.9 Battery Pack

The MSI-4260 is powered by a 12 volt Sealed Lead Acid rechargeable battery.
The battery will operate for up to 100 hours (depending on LED brightness setting)

before requiring recharging.
In order to conserve battery life, the scale includes an Automatic Power Off Mode

which senses operational status for no activity after 15, 30, 45, or 60 minutes, and

turns the scale off.
An additional battery saving feature is the Automatic Sleep Mode. This feature

preserves battery life by dimming the display after 5, 15, or 30 minutes of no scale

activity.
Charging time for a completely discharged battery is up to 8 hours. A spare battery

pack is recommended to keep the MSI-4260 in continuous operation.

Note

To obtain maximum service life from your batteries they should be stored
between -4°F and 122°F (-20°C and +50°C). Stored batteries should be
recharged every three months. Battery is fully charged when the status
indicator is flashing.

1.9.1

Battery Life

The MSI-4260 battery life depends on a number of factors:

• Brightness of the LED Display and number of segments lit.
• Amount of RF activity, and the age.
• Condition of the SLA (sealed lead acid) battery.

The MSI-4260 will automatically turn the scale off when the SLA battery drops to

approximately 10.5V. You must recharge the battery when this happens.

Note

Leaving a discharged battery in the scale, which has a maintenance
battery drain, can result in a deep discharged battery which will shorten
its service life.

SLA batteries do not suffer from memory effects and actually benefit from frequent

recharging. Recharge the battery whenever it is convenient even when it still has

available life.
Due to the maintenance discharge imposed on the battery by the MSI-4260

electronics, do not store the MSI-4260 with the battery inside. Remove the battery

if it will not be used for more than 2 weeks.

1.9.2

Battery Use Guidelines

• Recharge whenever convenient. Do not wait for the scale to shut itself off if your

work situation permits.

• If you need the scale continuously, keep a fully charged spare battery. Replace

the drained battery as close as possible to the low battery warning, or earlier.

• SLA Batteries that have not been deep discharged should withstand 500 to 1500

charging cycles.

• The low battery warning will indicate about 2-4 hours of additional use before

the MSI-4260 turns itself off.

• If the MSI-4260 is not going to used again soon, remove the SLA battery to

prevent deep discharge while the unit is in storage.

• Recycle the battery to an authorized recycling center when average life drops to

20 hours or less.

Advertising