7 total mode, Yqf $/rdg )lowu, L + $/$67 – Rice Lake MSI-4260 Port-A-Weigh User Manual

Page 32: Wrwd/ wwo2q, 6wruh, Total mode setup, Figure 4-8. total mode setup

Advertising
background image

28 MSI-4260 Port-A-Weigh Operator’s Manual

4.7 Total Mode

The MSI-4260 can keep track of all weighments using the Total feature. Either

manual total, which totals by pushing a configured USER key on the front panel or

the RF Remote, or Auto-Total, which can be used to automatically add up each

weighment. See the Total mode descriptions for details on the various Total modes.

To use Manual Total, you must also program a User Key. Auto Total modes do not

need a user key, but if a User key is setup for Total, then it will function as a total on /

total off.

1)

With the 4260 off, press and hold
the

USER

key, then press the

POWER

key.

...or while the 4260 is on, press

USER

and

POWER

simultaneously.

2)

The first item of the Setup Menu
is “Func1”. Scroll to “totaL” with
the

USER

key.

3)

To setup the Total Mode, press

TARE

. The current Total Mode

setting is displayed.

4)

Select the Total Mode by scrolling
through the choices with the

USER

key.

In this example, we’ll set the Total Mode

to the Auto-High mode. The Auto High

mode uses the highest stable reading

as the total value, and totals when the

load is removed.

5)

When the desired Total Mode
setting is displayed, press

TARE

.

The next item in the Setup Menu
appears.

6)

Either press

ZERO

to exit Setup

and store all changes, or
continue to another Setup Menu
item using the

USER

Key.

Total Mode Setup

)YQF

$/RDG

)LOWU

Next Setup Menu Item

2))

blinking, Total Off

$+L +

$/$67

Total on stable load

Total highest stable Load

Total last stable load

WRWD/

WWO2Q

Total with pushbutton

Store and return to

weight display

6WRUH

USER

F

USER

F

Hold

USER

F

esc

POWER

USER

F

USER

F

USER

F

USER

F

TARE

T

TARE

T

ZERO

O

sto

Cancel all setup

changes

esc

POWER

Figure 4-8. Total Mode Setup