1.10 Comm Port

The MSI-4260 has a single Comm Port allowing access to the embedded ScaleCore

through the Terminal Access Mode or MSI Software. The Terminal Access Mode is

used for updating scale firmware while MSI Software can be used for calibration and

configuration, backup and adjusting scale settings. This Comm Port is not intended

for output use as it is usually impractical to use a cable connected port on a Crane

Scale.

1.10.1 Comm Port Cables

The MSI-4260 comes standard with one Comm Port Cable wired for RS-232 (MSI P/

N 501705-0001) following the AT standard for 9 pin serial cables (DCE). An un-

terminated cable is available (MSI P/N 12023) if you wish to wire your own serial

cable for RS-232.
Comm Port Cable Color Code RS-232

• Brown – Transmit output from CellScale, connect to receive of DTE.
• Black – Receive input to CellScale, connect to transmit of DTE.
• Grey – CTS Input to CellScale. Connect to RTS or RTR output of DTE.
• White – RTS/RTR output from CellScale. Connect to CTS input of DTE.
• Blue – Signal Ground
• Drain Wire – Connect to metal shell.

1

2

3

4

5

6

7

8

(NC) 9

Brown (TD)

Black (RD)

Blue (GND)

Grey (CTS)

White (RTS)

Jumper 1-6-4

RS-232 DCE

9-Pin Female ‘D’

Solder Cup View

Standard wiring for direct

4260 to Computer connection

1

2

3

4

5

6

7

8

9 (NC)

Brown (TD)

Black (RD)

Blue (GND)

Grey (CTS)

White (RTS)

Jumper 1-6-4

RS-232 DTE

9-Pin Male ‘D’

Solder Cup View

Wiring for direct 4260 to

Printer/Scoreboard connection

Figure 1-4 Comm Port Cable Assignments