3 msi-4260 annunciators – Rice Lake MSI-4260 Port-A-Weigh User Manual

Page 9

Advertising
background image

Introduction 5

1.3 MSI-4260 Annunciators

The MSI-4260 uses blue and red LEDs to indicate weight mode and other
information.

The STABLE annunciator indicates that the weight has settled within
the motion window (usually ±1d). When this symbol is off the scale
will not zero, tare, or totalize.

0

Center-of-Zero – Indicates the weight is within 1/4d of zero.

PK

PEAK - Indicates the scale is in peak hold mode.

NET

NET - Indicates the scale is in Net weight mode.

A Tare weight is subtracted from the gross weight.

TTL

TOTAL - (Blue LED) Indicates the scale is displaying the Total weight.

This is a temporary display lasting less than 5 seconds.

x1K

X1000 - (Blue LED) Usually used in conjunction with the TOTAL LED
to allow accumulation of weight beyond the 5-digit display capacity.

BT

LO BATT - Appears when approximately 10% of battery life remains,
LED blinks when automatic shutdown is eminent.

kg

kg - (Red LED) Indicates weight display is in kilograms.

lb

lb - (Red LED) Indicates weight display is in pounds.

SET POINTS - User programmable set points for early overload
warnings.

Blue LED - Setpoint 1
Green LED = Setpoint 2

Red LED - Setpoint 3

ACK - Acknowledge LED is used to provide feedback to the
operator that incoming remote commands have been received
(Green LED).

Also used for acknowledging successful Auto-Total operations.

Advertising