3 printer / serial output setup, 1 control modes, 4 standard print strings – Rice Lake MSI-4260 Port-A-Weigh User Manual

Page 51: Control modes, Gross, Tare, 4 standard print strings 1

Advertising
background image

RF Remote Display Option 47

7.3 Printer / Serial Output Setup

The RS-232 Comm Port is capable of outputting tension data. All the weight modes

the RF linked weight device can measure are available in user formatted form. The

Control Mode programs what causes the MSI-4260 to print. The modes are: 1) When

an assigned F-Key is pressed, one transmission of the selected string type is output. 2)

On Load – When the tension on the link is stable, one transmission will output. Then

the tension must return to zero to enable another print output. 3) Continuous -

Program the interval in seconds up to 65,535 seconds. Setting the interval to 0 will

set an interval as fast as the system can go. To disable printing set the control mode to

“OFF”.
The MSI-4260 Comm Port settings are independent of the print settings in the

connected MSI-8000. They reside only in the MSI-4260.
Far more complex print / serial strings can be introduced using MSI’s SCCMP setup

program. See SCCMP User Guide for more details.

7.3.1

Control Modes

The user can select four control modes:

1. User – Printing is controlled by the operator pushing the PRINT key (usually

F3).

2. Load – One print output when a stable load is reached. The scale must return to

near zero before another print will occur. Other configurations of “On Load” are

available using the SCCMP program.

3. Continuous – The MSI-8000 will continuously output the data at a rate

controlled by the “rAtE” (RATE) menu.

4. OFF – Printing is disabled. Power consumption is lower with print off.

7.4 Standard Print Strings

1

- Current tension. Fixed output length: 16. Leading zeros suppressed except for

the LSD.

TTTTTTT

sp

UU

sp

MMMMM

crlf

where TTTTTTT is tension data with -sign if necessary. UU is the units, MMMMM is
the tension mode which for “1” is either NET or GROSS.

2

- Net tension. Fixed output length: 16. Leading zeros suppressed except for the

LSD.

TTTTTTT

sp

UU

sp

NET

spspcrlf

3

- Gross Tension. Fixed output length: 16. Leading zeros suppressed except for

the LSD.

TTTTTTT

sp

UU

sp

GROSS

crlf

4

-

Tare Weight. Fixed output length: 16. Leading zeros suppressed except for the

LSD.

TTTTTTT

sp

UU

sp

TARE

crlf

Advertising