User Defined Function Keys 19

Weight is <1% of Capacity – The

USER

key functions as “View Total” only and

functions as View Total until the 1% threshold is exceeded to allow the next addition

to the total value.

AUTO TOTAL

The

USER

key under the AUTO TOTAL mode functions as Auto Total On / Auto

Total Off.
The Auto Mode has three variations which are programmed in the SETUP menu:

AutoLoad – Any settled weight above the ‘Rise above’ threshold will be

automatically totaled. Then the scale must fall below the ‘Drop below’ threshold

before another total is allowed.

AutoNorm – This mode takes the last settled weight to auto total with. The total

occurs only once the scale goes below the threshold. This allows the load to be

adjusted without a total occurring. Once the load is removed, the scale uses the

last settled reading for total.

AutoHigh – Similar to the AutoNorm mode except the scale uses the highest

settled reading. Useful for loads that can’t be removed all at once.

Note

Any Total Mode will not function while the scale is in motion. Make sure
the

is on. If the system fails to achieve stable readings, increase

the filter setting or increase the size of the scale division (d) in the Init Cal
procedure.

View Total

The Function key activates the Total weight display followed by the number of

samples. While the display is showing the Total, Total is cleared by pressing

ZERO

.

Net / Gross

Switches the display between Net and Gross modes. Net Weight is defined as Gross

Weight minus a Tare Weight.

Note

RF Remote Control, and the MSI-8000 have this function as a standard
feature. On the MSI-8000, you must configure a Function Key to Net/
Gross Mode to enable this feature.

To Switch Between Net Mode and Gross Mode:

1. Press the

USER

key (Setup to the Net/Gross function).

2. The

NET/GROSS

key will only function if a Tare value has been established.

3. Switching back to Gross mode from Net mode will not clear the Tare value. This

allows the operator to use the Gross Mode temporarily without having to

reestablish the Tare value. Only clearing the Tare or setting a new Tare will

change the tare value held before switching into Gross Mode.

OIML LFT units only: The NET/GROSS key is temporary action only. The Gross

weight is displayed for two seconds and then the display returns to the Net Mode. The

only way to return to permanent Gross readings is to clear the Tare (See Section 2.3).

PRINT

If print option is installed this menu choice will appear. The setup of the print function

is covered in the Option manual.

Advertising