50 MSI-4260 Port-A-Weigh Operator’s Manual

7.5 802.15.4 RF Network Setup

(MSI-8000 Connection)
When equipped with the 802.15.4 Option, the MSI-4260 can connect with an MSI-
8000
Remote Display or an 802.15.4 Modem. The MSI-4260 uses three numbers to

connect to an 802.15.4 piconet:

1. ScaleCore ID – This number is used to uniquely identify each ScaleCore device

in a Piconet. It has a range of 0-254 and must not be duplicated within the same

RF Channel. For the MSI-8000 as network coordinator, MSI recommends a

number for the MSI-4260 from 0-3 if multiple units will be connected to the
MSI-8000. If a single MSI-4260 is all that’s needed, then any number up to 254

is acceptable.

2. RF Channel – Establishes the base network that all interconnected devices must

match. This number must be in the range of 12-23.

3. Network ID – This is a 64 bit number that all interconnected devices must

match. The MSI-4260 limits this number to a max of 5 digits for a range of 0-

99999. Do not use a small number here to help avoid other 802.15.4 networks

that default to a Network ID of 0.

For all devices that must interconnect, the RF Channel and Network ID must match.

The ScaleCore ID must be unique. The MSI-4260 or other MSI RF equipment that is

a weight data source should be set to a ScaleCore ID of 0. Then if other slave devices

are added, they can be added in sequence.

3ULQW

U)

(WKQW

Serial Out Setup

rF Modem

Ethernet

RF MENU

2Q2II

6&LG

&KQO

QHWLG

RF On/Off

ScaleCore ID

RF Channel

Network ID

2Q

2II

RF On

RF Off

RF SETUP

Range 0-254

Range 12-23

Range 1 to 99999

Press Simultaneously

TARE

T

USER

F

Figure 7-4. RF Menu