10) Press

USER

key until the desired

print control mode is shown.

11) When the desired print mode is

shown, push

TARE

to save. The

next Print setup item, “rAte”
appears. If you have set
Continuous (Cont) as your print
control, proceed to step 12). For
any other Control mode jump to
step 15.

12)Press

TARE

to enter the Print

rate number entry screen. The
current print rate appears on the

LCD.

In this example, we’ll set the Print Rate

to an output rate of once every 2

seconds.

/R$G

&RQW

Function Key Prints

Print is disabled

UDWH

Next Print Menu Item

TARE

T

USER

F

USER

F



blinking

Example Value

The number represents the print

interval rate in seconds. Use 0 for the

fastest the MSI-8000 can go (~5 times

per second). To set a once a minute

transmission, set the rate to 60. To

set once per hour, set the rate to 3600, etc. Largest possible

entry is 65535 which is >18 hours.

TARE

T

13) Press

USER

to change the Print

rate. Scroll the number with the

USER

key. Enter each number

with the

TARE

key.

14) When the entire number is

displayed, press

TARE

again to

finalize the seconds entry. The
next Print Menu Item appears,
“String”.

15) Exit the Print Setup Menu by

pressing

ZERO

twice. The

message “Store” appears briefly
then normal system operation
starts.



blinking



blinking



fixed

6WUQ

3ULQW

6WRUH

USER

F

ZERO

O

sto

ZERO

O

sto

TARE

T

TARE

T

USER

F

RF Remote Display Option 49

Figure 7-3. Printer Output Menu (continued)