Introduction

3

Following power up, interface port selection occurs automatically upon detection of valid data. If the incoming
data flow stops and the host timeout period is achieved, partially received formats will be ignored and the port
detection process repeated.

Ethernet Connection

The Ethernet interface supports several menu-selectable modes. Depending on the length, the cable should be
Category/Type 3 or better. To order, ask for Rice Lake part number 103372. Installation documentation is
supplied with the interface option.

Parallel Connection

The parallel interface supports directional communications. Choose and connect cabling as follows:

For uni-directional communication, use a Centronics IEEE 1284 cable with a 36-pin male connector; or

For bi-directional communication, use an IEEE 1284 compliant cable with a 36-pin male connector (and
supporting host software).

USB Connection

The USB connection cable supports directional communications.

Serial Connection

The serial interface supports RS-232, RS-422, and RS-485 communications.

1.1.2

Split Communications Cable Installation

The SST3 printer enclosure comes with a unique cable installation assembly that ensures the interior of the unit
stays moisture free even during washdown conditions. The assembly allows the installer to eliminate the need to
cut cables and still maintain a watertight barrier. Use the following steps to install your cable of choice through
the split communications cable seal.

1. Using a 7/16” socket, remove the four nuts holding the split communications cable plate in place. Take

care in removing the nuts as they could slip and fall down between the plate and the printer enclosure.
Set the nuts aside.

Figure 1-2. Split Communications Cable Assembly in the SST3 Printer Enclosure

Four nuts