4 electrical connections, 6sct weight transmitter operator’s manual – Rice Lake SCT-10 User Manual

Page 10

Advertising
background image

6

SCT Weight Transmitter Operator’s Manual

1.4

Electrical Connections

• It is recommended that the negative side of the power supply be grounded.
• It is possible to power up to eight 350 ohm load cells or sixteen 700 ohm

load cells.

• Connect terminal “0 VDC” to the RS-485 common of the connected

instruments in the event that these receive alternating current input or that

they have an opto-isolated RS-485.

• In case of an RS-485 network with several devices it is recommended to

activate the 120 ohm termination resistance on the two devices located at the

ends of the network, see Section 2.5.1 “RS-485 Serial Communication” on

page 25

2 outputs: configurable setpoints or remote output management via protocol.
2 inputs (Default: SEMI-AUTOMATIC ZERO input 1; NET/GROSS input
2
): settable to have the following functions: SEMI-AUTOMATIC ZERO,
NET/GROSS, PEAK, or REMOTE CONTROL (see Section 2.6 “Outputs

And Inputs Configuration” on page 26).

13

1 2 3 4 5 6 7 8 9

1112

10

21

14 1516 1718 19 20

SH

LOAD CELLS IN PARALLEL

IN1

IN2

IN COM

OU

T1

OU

T2

+ RS

485

-

RS485

mA

V

mA-V COM

NET

0

kg

g

L

INPUTS

5-24Vdc

OUTPUTS

24Vdc

60mA

RS485

OUTPUT

12-24Vdc

ANALOG

RS485 termination

0

ESC

33

31

30

32

28

27

25

2324

26

29

22

34

+ 12-24

0 VDC

POWER

+ EX

-

EX

-

SIG

+ SI

G

-

EX

+ EX

-

SIG

+ SI

G

SH

-

EX

+ EX

-

SIG

+ SI

G

SH

-

EX

+ EX

-

SIG

+ SIG

SH

J1

J2

SCT

Current output: max load 300 Ohm

Voltage output: min. load 10 kOhm

- EXCITA

TION

+ EXCITATION

- SIG

NAL

+ SIGNA

L

- EXCITA

TION

+ EXCITATION

- SIGNAL

+ SIGNA

L

- EXCITA

TION

+ EXCITATION

- SIGNAL

+ SIGNA

L

- EXCITA

TION

+ EXCITATION

- SIGNAL

+ SIGNA

L

Advertising